37
Service Manual
Third edition, June 1997
1 = Correction to the tank’s reference point (Plug)
2 = Correction to the tank’s center of gravity (COG)
It is also possible to use two sets (1 or 2) of customized units
for each parameter. These can be scaled from the raw data
into the new units using the scale constants A, B and C. The
scaling is done according to the formula:
data (in custom units) = (raw data * A) / B + C.
You can also set the number of decimals to be presented on
the displays.